Hydrogen chloride gas Zinc/zinc oxides
Not combustible.
Ambient fire may liberate hazardous vapours.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
HEALTH | 3 | Short exposure could cause serious temporary or moderate residual injury (e.g. liquid hydrogen, sulfuric acid, calcium hypochlorite, hexafluorosilicic acid) | |
FIRE | 0 | Materials that will not burn under typical fire conditions, including intrinsically noncombustible materials such as concrete, stone, and sand. Materials that will not burn in air when exposed to a temperature of 820 °C (1,500 °F) for a period of 5 minutes.(e.g. Carbon tetrachloride) | |
REACT | 1 | Normally stable, but can become unstable at elevated temperatures and pressures (e.g. propene) | |
SPEC. HAZ. |
Advice for non-emergency personnel: Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
For personal protection see section 8.
Do not let product enter drains.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts.
For disposal see section 13.
For precautions see section 2.2.
Handle under nitrogen, protect from moisture. Store under nitrogen.
Tightly closed. Dry. strongly hygroscopic
Storage class (TRGS 510): 8B: Non-combustible, corrosive hazardous materials
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm Break through time: 480 min
Material tested:Dermatril? (KCL 740 / Aldrich Z677272, Size M)
Splash contact Material: Nitrile rubber
Minimum layer thickness: 0,11 mm Break through time: 480 min
Material tested:Dermatril? (KCL 740 / Aldrich Z677272, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
protective clothing
required when dusts are generated.
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Recommended Filter type: Filter type P2
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Do not let product enter drains.
No data available
No data available
The product is chemically stable under standard ambient conditions (room temperature) .
Violent reactions possible with:
sodium
Strong oxidizing agents
various metals
In the event of fire: see section 5
- 96 h
Remarks: (ECHA)
static test EC50 - Daphnia magna (Water flea) - 0,33 mg/l - 48 h (OECD Test Guideline 202)
(OECD Test Guideline 201)
(ISO 9509)
Remarks: (referred to the cation)
The methods for determining biodegradability are not applicable to inorganic substances.
Bioaccumulation Channa punctata - 45 d
at 27 °C(zinc chloride)
Bioconcentration factor (BCF): 0,4
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
IncompatibilitiesAqueous solutions are strongly acidic. Incompatible with bases and potassium. Incompatible with strong oxidizers (chlorates, nitrates, peroxides, permanganates, perchlorates, chlorine, bromine, fluorine, etc.); contact may cause fires or explosions. Keep away from alkaline materials, strong bases, strong acids, oxoacids, epoxides. Corrosive to metals.
Waste DisposalDump in water; add soda ash and stir, then neutralize and flush to sewer with water. Alternatively, zinc chloride may be recovered from spent catalysts and used in acrylic fiber spinning solutions.
ADR/RID: 2331 IMDG: 2331 IATA: 2331
| ADR/RID: ZINC CHLORIDE, ANHYDROUS IMDG: ZINC CHLORIDE, ANHYDROUS | |
IATA: Zinc chloride, anhydrous | ||
14.3 | Transport hazard class(es) ADR/RID: 8 IMDG: 8 | IATA: 8 |
14.4 | Packaging group ADR/RID: III IMDG: III | IATA: III |
14.5 | Environmental hazards ADR/RID: yes IMDG Marine pollutant: yes | IATA: no |
14.6 | Special precautions for user No data available | |
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.