Carbon oxides Nitrogen oxides (NOx) Combustible.
Development of hazardous combustion gases or vapours possible in the event of fire.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
HEALTH | |||
FIRE | 1 | Materials that require considerable preheating, under all ambient temperature conditions, before ignition and combustion can occur. Includes some finely divided suspended solids that do not require heating before ignition can occur. Flash point at or above 93.3 °C (200 °F). (e.g. mineral oil, ammonia) | |
REACT | 3 | Capable of detonation or explosive decomposition but requires a strong initiating source, must be heated under confinement before initiation, reacts explosively with water, or will detonate if severely shocked (e.g. ammonium nitrate, cesium, hydrogen peroxide) | |
SPEC. HAZ. |
For personal protection see section 8.
Do not let product enter drains.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully. Dispose of properly. Clean up affected area. Avoid generation of dusts.
For disposal see section 13.
Work under hood. Do not inhale substance/mixture.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
For precautions see section 2.2.
Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible
only to qualified or authorized persons.
Recommended storage temperature 2 - 8 °C
Moisture sensitive.
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
protective clothing
required when dusts are generated.
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Recommended Filter type: Filter type P3
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Do not let product enter drains.
Surface tension 72,86 mN/m at 1g/l at 20 °C
- OECD Test Guideline 115
The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
The product is chemically stable under standard ambient conditions (room temperature) .
No data available
Contact with acids liberates very toxic gas. Avoid moisture. no information available
Strong oxidizing agents, Strong reducing agents, Bases, acids, Iron and iron salts., Steel (all types and surface treatments), Brass, Lead
In the event of fire: see section 5
- 96 h
static test EC50 - Daphnia magna (Water flea) - 3,2 mg/l - 48 h (OECD Test Guideline 202)
Biodegradability aerobic - Exposure time 28 d
Result: 0 % - Not readily biodegradable. (OECD Test Guideline 301E)
No data available
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
Cyanamide may polymerize at tempera- tures above 122℃ , or on evaporation of aqueous solutions. Reacts with acids, strong oxidants, strong reducing agents such as hydrides and water, causing explosion and toxic hazard. Attacks various metals.
See www.retrologistik.com for processes regarding the return of chemicals and
containers, or contact us there if you have further questions.
Waste DisposalAdd excess alkaline calcium hypochlorite with agitation. Flush to sewer after 24 hours. Cyanamide can also be destroyed in an incinerator equipped with afterburner and scrubber.
ADR/RID: 2923 IMDG: 2923 IATA: 2923
ADR/RID: CORROSIVE SOLID, TOXIC, N.O.S. (Cyanamide) IMDG: CORROSIVE SOLID, TOXIC, N.O.S. (Cyanamide)
IATA: Corrosive solid, toxic, n.o.s. (Cyanamide)
ADR/RID: 8 (6.1) IMDG: 8 (6.1) IATA: 8 (6.1)
ADR/RID: III IMDG: III IATA: III
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.