Carbon oxides Nitrogen oxides (NOx) Combustible.
Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating.
Development of hazardous combustion gases or vapours possible in the event of fire.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
HEALTH | 3 | Short exposure could cause serious temporary or moderate residual injury (e.g. liquid hydrogen, sulfuric acid, calcium hypochlorite, hexafluorosilicic acid) | |
FIRE | 1 | Materials that require considerable preheating, under all ambient temperature conditions, before ignition and combustion can occur. Includes some finely divided suspended solids that do not require heating before ignition can occur. Flash point at or above 93.3 °C (200 °F). (e.g. mineral oil, ammonia) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
For personal protection see section 8.
Do not let product enter drains.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully with liquid-absorbent material (e.g.
Chemizorb?). Dispose of properly. Clean up affected area.
For disposal see section 13.
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
For precautions see section 2.2.
Tightly closed. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons.
Hygroscopic.
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Use equipment for eye protection tested and approved under appropriate
government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm Break through time: 480 min
Material tested:KCL 741 Dermatril? L
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Splash contact Material: Nitrile rubber
Minimum layer thickness: 0,11 mm Break through time: 480 min
Material tested:KCL 741 Dermatril? L
protective clothing
Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Do not let product enter drains.
No data available
Forms explosive mixtures with air on intense heating.
A range from approx. 15 Kelvin below the flash point is to be rated as critical.
The product is chemically stable under standard ambient conditions (room temperature) .
Violent reactions possible with:
Oxidizing agents acids
Caution! In contact with nitrites, nitrates, nitrous acid possible liberation of nitrosamines!
Copper, Zinc
In the event of fire: see section 5
EC50 - Daphnia magna (Water flea) - 190 mg/l - 48 h
Biodegradability Result: 0 % - Not readily biodegradable.
(OECD Test Guideline 301C)
No data available
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
See www.retrologistik.com for processes regarding the return of chemicals and
containers, or contact us there if you have further questions.
IncompatibilitiesContact with cellulose nitrate may cause fires upon contact. Reacts with Oxidizers, strong acids.
ADR/RID: 2735 IMDG: 2735 IATA: 2735
ADR/RID: POLYAMINES, LIQUID, CORROSIVE, N.O.S. (2-(2-Aminoethylamine)ethanol) IMDG: POLYAMINES, LIQUID, CORROSIVE, N.O.S. (2-(2-Aminoethylamine)ethanol) IATA: Polyamines, liquid, corrosive, n.o.s. (2-(2-Aminoethylamine)ethanol)
ADR/RID: 8 IMDG: 8 IATA: 8
ADR/RID: II IMDG: II IATA: II
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.