Carbon oxides Combustible.
Pay attention to flashback.
Vapors are heavier than air and may spread along floors.
Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.
In the event of fire, wear self-contained breathing apparatus.
Remove container from danger zone and cool with water. Prevent fire extinguishing water from contaminating surface water or the ground water system.
HEALTH | 1 | Exposure would cause irritation with only minor residual injury (e.g. acetone, sodium bromate, potassium chloride) | |
FIRE | 3 | Liquids and solids (including finely divided suspended solids) that can be ignited under almost all ambient temperature conditions . Liquids having a flash point below 22.8 °C (73 °F) and having a boiling point at or above 37.8 °C (100 °F) or having a flash point between 22.8 and 37.8 °C (73 and 100 °F). (e.g. gasoline, acetone) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition.
Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8.
Do not let product enter drains. Risk of explosion.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up with liquid-absorbent material (e.g. Chemizorb? ). Dispose of properly. Clean up affected area.
For disposal see section 13.
Avoid generation of vapours/aerosols.
Keep away from open flames, hot surfaces and sources of ignition.Take precautionary measures against static discharge.
Change contaminated clothing. Wash hands after working with substance. For precautions see section 2.2.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition.
Handle and store under inert gas. Hygroscopic.
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0,4 mm Break through time: 480 min
Material tested:Camatril? (KCL 730 / Aldrich Z677442, Size M)
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Splash contact Material: Chloroprene
Minimum layer thickness: 0,65 mm Break through time: 120 min Material tested:KCL 720 Camapren?
Flame retardant antistatic protective clothing.
Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Do not let product enter drains. Risk of explosion.
Minimum ignition energy
0,65 mJ
Conductivity < 0,1 μS/cm
Surface tension 20,8 mN/m at 25,0 °C
Relative vapor density
2,07
Vapors may form explosive mixture with air.
Reacts with air to form peroxides.
The product is chemically stable under standard ambient conditions (room temperature) .
No data available
Warming.
Acid anhydrides, Aluminum, Halogenated compounds, Acids, Strong oxidizing agents
In the event of fire: see section 5
(OECD Test Guideline 203)
EC50 - Daphnia magna (Water flea) - 13.299 mg/l - 48 h Remarks: (IUCLID)
Remarks: (IUCLID)
Remarks: (Lit.)
Biodegradability aerobic - Exposure time 5 d
Result: 53 % - Readily biodegradable. (Directive 67/548/EEC, Annex V, C.6)
Theoretical oxygen demand
2.400 mg/g Remarks: (Lit.)
Ratio BOD/ThBOD 49 %
Remarks: (IUCLID)
No bioaccumulation is to be expected (log Pow <= 4).
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
IncompatibilitiesIncompatible with oxidizing agents such as hydrogen peroxide and nitric acid, which cause decomposition. Isopropyl alcohol may be salted out from aqueous mixtures by the addition of sodium chloride, sodium sulfate, and other salts, or by the addition of sodium hydroxide.
ADR/RID: 3 IMDG: 3 IATA: 3
ADR/RID: II IMDG: II IATA: II
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.