Carbon oxides Combustible.
Pay attention to flashback.
Vapors are heavier than air and may spread along floors. Risk of dust explosion.
Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Remove container from danger zone and cool with water. Prevent fire extinguishing water from contaminating surface water or the ground water system.
HEALTH | 1 | Exposure would cause irritation with only minor residual injury (e.g. acetone, sodium bromate, potassium chloride) | |
FIRE | 3 | Liquids and solids (including finely divided suspended solids) that can be ignited under almost all ambient temperature conditions . Liquids having a flash point below 22.8 °C (73 °F) and having a boiling point at or above 37.8 °C (100 °F) or having a flash point between 22.8 and 37.8 °C (73 and 100 °F). (e.g. gasoline, acetone) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition.
Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8.
Do not let product enter drains. Risk of explosion.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully with liquid-absorbent material (e.g.
Chemizorb?). Dispose of properly. Clean up affected area.
For disposal see section 13.
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Keep away from open flames, hot surfaces and sources of ignition.Take precautionary measures against static discharge.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
For precautions see section 2.2.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition. Keep locked up or in an area accessible only to qualified or authorized persons.
Test for peroxide formation periodically and before distillation.
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Full contact Material: Viton?
Minimum layer thickness: 0,7 mm Break through time: 480 min
Material tested:Vitoject? (KCL 890 / Aldrich Z677698, Size M)
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Splash contact Material: Nitrile rubber
Minimum layer thickness: 0,4 mm Break through time: 10 min
Material tested:Camatril? (KCL 730 / Aldrich Z677442, Size M)
Flame retardant antistatic protective clothing.
required when vapours/aerosols are generated.
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Recommended Filter type: Filter type ABEK
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Do not let product enter drains. Risk of explosion.
Surface tension 70,7 mN/m at 1g/l at 23 °C
- OECD Test Guideline 115
Relative vapor density
3,11 - (Air = 1.0)
Formation of peroxides possible.
Vapors may form explosive mixture with air.
The product is chemically stable under standard ambient conditions (room temperature) . Stable under recommended storage conditions.
No data available
Warming. Moisture.
Oxidizing agents, Strong acids, Strong oxidizing agents
Peroxides
In the event of fire: see section 5
Remarks: The value is given in analogy to the following substances: Tegdme
semi-static test EC50 - Daphnia magna (Water flea) - 4.000 mg/l - 48 h
(OECD Test Guideline 202)
9.120 mg/l - 72 h
(OECD Test Guideline 201)
Biodegradability aerobic - Exposure time 48 d
Result: 16 % - According to the results of tests of biodegradability this product is not readily biodegradable.
(OECD Test Guideline 302B)
Chemical Oxygen Demand (COD)
1.700 mg/g
Remarks: (External MSDS)
Due to the distribution coefficient n-octanol/water, accumulation in organisms is not expected.
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
ADR/RID: 2252 IMDG: 2252 IATA: 2252
| ADR/RID: 1,2-DIMETHOXYETHANE IMDG: 1,2-DIMETHOXYETHANE | |
IATA: 1,2-Dimethoxyethane | ||
14.3 | Transport hazard class(es) ADR/RID: 3 IMDG: 3 | IATA: 3 |
14.4 | Packaging group ADR/RID: II IMDG: II | IATA: II |
14.5 | Environmental hazards ADR/RID: no IMDG Marine pollutant: no | IATA: no |
14.6 | Special precautions for user No data available | |
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.