Hazardous to the aquatic environment, short-term (Acute) - Category Acute 1
Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 1
H410 Very toxic to aquatic life with long lasting effects
P273 Avoid release to the environment.
P391 Collect spillage. Hazardous to the aquatic environment
P501 Dispose of contents/container to..…
P273 Avoid release to the environment.
P391 Collect spillage.
none
P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
no data available
Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.
Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.
Rinse with pure water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.
no data available
Basic treatment: Establish a patent airway. Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if needed. Administer oxygen by nonrebreather mask at 10 to 15 L/min. Monitor for pulmonary edema and treat if necessary . Monitor for shock and treat if necessary . Anticipate seizures and treat if necessary . For eye contamination, flush eyes immediately with water. Irrigate each eye continuously with normal saline during transport . Do not use emetics. For ingestion, rinse mouth and administer 5 ml/kg up to 200 ml of water for dilution if the patient can swallow, has a strong gag reflex, and does not drool . Cover skin burns with dry sterile dressings after decontamination . Poison A and B
Use dry chemical, carbon dioxide or alcohol-resistant foam.
no data available
Wear self-contained breathing apparatus for firefighting if necessary.
Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.
Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.
Collect and arrange disposal. Keep the chemical in suitable and closed containers for disposal. Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.
Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.
Store the container tightly closed in a dry, cool and well-ventilated place. Store apart from foodstuff containers or incompatible materials.
no data available
no data available
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.
Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).
Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.
no data available
no data available
77°C
504.5°C at 760 mmHg
no data available
no data available
258.9°C
no data available
no data available
no data available
no data available
log Kow = 5.40
5.35E-11mmHg at 25°C
1.588 g/cm3
no data available
no data available
no data available
Stable in neutral media , but less stable under alkaline or acidic conditions.
no data available
no data available
no data available
When heated to decomposition it emitstoxic fumes of/ hydrogen bromide/.
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
no data available
AEROBIC: Two sandy soil types from Florida were treated with bromopropylate and sampled at various intervals over 16 weeks(1); representative rates of biodegradation are given below. In the Lakeland soil sample with higher organic matter content, the concentration was reduced from 1.01 ppm to 0.65 after 1 week and 0.33 ppm after 8 weeks(1). In the Leon soil sample with lower organic matter content, bromopropylate was degraded more slowly from an initial concentration of 1.12 ppm to 0.99 after 1 week and 0.47 after 8 weeks(1). Half-lives of bromopropylate in Lakeland soil were 2.5, 8, and 12 weeks at bromopropylate concentrations of 1.0, 0.6, and 0.3 ppm, respectively(1). Half-lives of bromopropylate in Leon soil were 4, 13, and 12 weeks at bromopropylate concentrations of 1.0, 0.6, and 0.3 ppm, respectively(1).
An estimated BCF of 2,900 was calculated for bromopropylate(SRC), using a log Kow of 5.40(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is very high(SRC).
The Koc of bromopropylate is estimated as 21,000(SRC), using a log Kow of 5.40(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that bromopropylate is expected to be immobile in soil.
no data available
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: no data available
IMDG: no data available
IATA: no data available
ADR/RID: Yes
IMDG: Yes
IATA: Yes
no data available
no data available
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.