Carbon oxides Sulfur oxides
Hydrogen chloride gas Combustible.
Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air at elevated temperatures.
Development of hazardous combustion gases or vapours possible in the event of fire.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Remove container from danger zone and cool with water. Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
HEALTH | 2 | Intense or continued but not chronic exposure could cause temporary incapacitation or possible residual injury (e.g. diethyl ether, ammonium phosphate, iodine) | |
FIRE | 2 | Must be moderately heated or exposed to relatively high ambient temperature before ignition can occur and multiple finely divided suspended solids that do not require heating before ignition can occur. Flash point between 37.8 and 93.3 °C (100 and 200 °F). (e.g. diesel fuel, sulfur) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition.
Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8.
Do not let product enter drains. Risk of explosion.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully with liquid-absorbent material (e.g.
Chemizorb?). Dispose of properly. Clean up affected area.
For disposal see section 13.
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Keep away from open flames, hot surfaces and sources of ignition.Take precautionary measures against static discharge.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
For precautions see section 2.2.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and
sources of ignition. Keep locked up or in an area accessible only to qualified or authorized persons.
Recommended storage temperature 2 - 8 °C
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
required
Flame retardant antistatic protective clothing.
required when vapours/aerosols are generated.
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Recommended Filter type: Filter type ABEK
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Do not let product enter drains. Risk of explosion.
No data available
Vapor/air-mixtures are explosive at intense warming.
The product is chemically stable under standard ambient conditions (room temperature) .
No data available
Heating.
Strong oxidizing agentsStrong bases
In the event of fire: see section 5
No data available
No data available
No data available
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
ADR/RID: 2929 IMDG: 2929 IATA: 2929
ADR/RID: TOXIC LIQUID, FLAMMABLE, ORGANIC, N.O.S. (2-Chloroethyl ethyl sulphide) IMDG: TOXIC LIQUID, FLAMMABLE, ORGANIC, N.O.S. (2-Chloroethyl ethyl sulphide) IATA: Toxic liquid, flammable, organic, n.o.s. (2-Chloroethyl ethyl sulphide)
ADR/RID: 6.1 (3) IMDG: 6.1 (3) IATA: 6.1 (3)
ADR/RID: II IMDG: II IATA: II
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.